The general energy balance equation can describe any process:
\[\frac{d(m_{sys}H_{sys})}{dt} = \sum_i \dot{m}_{in,i} H_{in,i} - \sum_j \dot{m}_{out,j} H_{out,j} + \sum_k \dot{Q}_k + \sum_l \dot{W}_l\]
To solve the energy balance, the enthalpy of the system, and of the flow in & out, must be known.
Enthalpy is affected by:
The balance asks for \(H_{in}\), \(H_{out}\) values, not changes.
Enthalpy changes between two states are always well defined:
\[\Delta H_{state\:1\rightarrow\:state\:2} = H_{state\:2} - H_{state\:1} \quad \checkmark\]
For a sensible heat effect:
\[\Delta H_{1\rightarrow 2} = \int_{T_1}^{T_2} C_P\,dT = \langle C_P \rangle\,(T_2 - T_1)\]
Pick a reference state and set its enthalpy as zero
\[H_{ref} \equiv 0\]
Then any state has an “absolute” enthalpy measured from that reference:
\[H_{state\:1} = \underbrace{H_{ref}}_{=\,0} + \Delta H_{ref\:\rightarrow\:state\:1} = \Delta H_{ref\:\rightarrow\:state\:1}\]
An “absolute” enthalpy is really just a change — measured from a reference point.
\[H_1 = \displaystyle\int_{T_{ref}}^{T_1} C_P dT + H_{ref}\]
\[H_2 = \displaystyle\int_{T_{ref}}^{T_2} C_P dT + H_{ref}\]
\[\Delta H = H_2 - H_1 = \displaystyle\int_{T_1}^{T_2} C_P dT\]
The individual values \(H_1\) and \(H_2\) depend on the reference state. The difference \(H_2 - H_1\) does not.
Enthalpy is a state function — the path between two states does not change \(\Delta H\).
So every calculation can pass through the reference state:
\[\Delta H_{1\rightarrow 2} = \underbrace{\Delta H_{1\rightarrow ref}}_{-H_1} + \underbrace{\Delta H_{ref\rightarrow 2}}_{H_2}\]
Steady-state heater, one stream in, one out, no work:
\[\dot{Q} = \dot{m}\left(H_{out} - H_{in}\right)\]
With \(H = C_P (T - T_{ref})\) for both streams:
\[\dot{Q} = \dot{m}\left[C_P(T_{out} - T_{ref}) - C_P(T_{in} - T_{ref})\right]\]
\[\dot{Q} = \dot{m} C_P (T_{out} - T_{in})\]
\(T_{ref}\) has vanished. Any reference state gives the same answer.
If it cancels, why not always work with \(\Delta T\) directly?
A reference state is freely chosen — but it must be fully specified:
Important
Use the same reference state for every enthalpy term in a calculation.
Choose one that is convenient for the data or problem.
Two rules of thumb:
Always state the reference explicitly in the write-up.
A reference state is a tool, not a requirement.
The energy balance only ever contains enthalpy differences. If those differences can be written down directly, the reference state never has to be named.
Rule of thumb
If every enthalpy term in the balance can be paired up as \(H_{out} - H_{in}\) for the same species in the same phase, skip the reference state.
Heating water from 20 \(^\circ\)C to 80 \(^\circ\)C:
\[\dot{Q} = \dot{m}\left(H_{out} - H_{in}\right) = \dot{m} C_P (T_{out} - T_{in})\]
No reference states are needed
Writing \(H_{in} = C_P(20 - T_{ref})\) and \(H_{out} = C_P(80 - T_{ref})\) gives the same answer
Much tabulated data is published as a \(\Delta H\), not an \(H\):
\(\Delta H_{vap}\) — latent heat of vaporisation
\(\Delta H^\circ_{rxn}\) — heat of reaction
\(\Delta H_{soln}\) — heat of solution or mixing
These are used directly. Boiling 2 kg/s of water at 100 \(^\circ\)C:
\[\dot{Q} = \dot{m}\,\Delta H_{vap} = 2 \times 2257 = 4514\ \text{kW}\]
Enthalpy is a state function, so any convenient path works — a reference state is just one particular choice of path.
Adiabatic reactor: react at \(T_{in}\), then heat the products to \(T_{out}\)
\[\Delta H_{sys} = \underbrace{\xi\,\Delta H_{rxn}(T_{in})}_{\text{reaction}} + \underbrace{\sum_k n_k C_{P,k}(T_{out} - T_{in})}_{\text{sensible heat}} = 0\]
Every term is a difference between two real states of the process.
There is no hard and fast rule ::: {.incremental} - Simple problem — one or two streams, one species, no reaction? Work with differences
Complex problem — several streams, phase changes, reactions, recycles? Use a reference state
Steam tables or \(\Delta H^\circ_f\) data? These already use a reference state :::
Important
Whichever method is used, state it explicitly. An unstated reference state and an unstated path are equally hard to trobleshoot.
Air is heated in a steady-state duct heater from 25 \(^\circ\)C to 150 \(^\circ\)C at a mass flow rate of 0.50 kg s\(^{-1}\). \(C_P = 1.01\) kJ kg\(^{-1}\) K\(^{-1}\)
Using a reference state of air, gas, 0 \(^\circ\)C, 1 atm:
Repeat the heat calculation of Example 5.1 without a reference state
Two liquid streams are combined continuously at steady state:
| Stream | Fluid | \(\dot{m}\) (kg s\(^{-1}\)) | \(T\) (\(^\circ\)C) | \(C_P\) (kJ kg\(^{-1}\) K\(^{-1}\)) |
|---|---|---|---|---|
| A | Ethanol | 1.50 | 20 | 2.44 |
| B | Water | 0.80 | 75 | 4.18 |
There is no work or heat loss. Assume heat capacities are constant, and neglect the enthalpy of mixing.